AuraMineClosure Intelligence Platform

Monitoring & Proxy Optimiser

The commercial argument of the platform: cheap in-situ measurements can stand in for laboratory analysis where the relationship is strong enough, and only where it is.

Projected annual saving

45,200

PHP-equivalent, analytical spend only

Analyst hours released

250

Redirected to field and community work

Regulatory coverage

Unchanged

SN5 and SN6 retain full laboratory analysis

Station-by-station recommendation

StationCurrent regimeRecommended regimeConfidenceSaving
SN1Monthly full laboratory suiteMonthly in-situ pH + EC proxy, annual laboratory auditStable, consistently within guidelineHigh8,400
SN2Monthly full laboratory suiteQuarterly in-situ proxy, annual laboratory auditControl station, low varianceHigh9,100
SN3Monthly full laboratory suiteRetain monthly laboratory suite (manganese anomaly open)Anomaly under verification — no reduction recommendedModerate—
SN4Fortnightly full laboratory suiteFortnightly in-situ proxy, quarterly laboratory auditProxy relationship strong across seasonsHigh11,200
SN5Fortnightly full laboratory suiteRetain full laboratory analysisModel uncertainty highest; regulatory reporting stationHigh—
SN6Fortnightly full laboratory suiteRetain full laboratory analysisTreatment performance station; proxy residuals widest hereModerate—
SN7Monthly full laboratory suiteMonthly in-situ proxy, biannual laboratory auditCommunity-relevant intake — audit frequency kept above minimumHigh7,600
SN8Monthly full laboratory suiteQuarterly in-situ proxy, annual laboratory auditDownstream compliance point, consistently cleanHigh8,900

Applying writes an entry to the assurance log with the evidence and confidence at the time.

Proxy prediction vs laboratory result

Agreement is tight below 1.2 mg/L and loosens above it — which is exactly why SN5 and SN6 keep full analysis.

Laboratory copper (mg/L)Proxy prediction (mg/L)
Proxy substitution
Flagship insight
ConfidenceHigh 0.86

In-situ pH and electrical conductivity predict laboratory dissolved-copper results with R² 0.83 across 98 samples, so routine monitoring at 5 of 8 stations can shift to low-cost proxies while full laboratory analysis is retained at SN5 and SN6.

Projected reduction: 45,200 PHP-equivalent per year in analytical spend and 250 analyst hours released, at unchanged regulatory coverage.

Recommended action

Apply the recommended proxy regime at SN1, SN2, SN4, SN7 and SN8, and keep full laboratory analysis at SN5 and SN6.

Owner: Monitoring Lead · By: Before the October sampling round · Advisory only, a named human role decides.